The GeniaAir Max is your ideal companion for year-round comfort, offering reliable heating and cooling with top energy efficiency. Whether your home has modern systems or older radiators, this heat pump ensures warmth in winter and refreshing coolness in summer. With flow temperatures reaching up to 75°C for heating and 70°C for hot water, it’s designed to meet your needs, no matter the season. Operating at whisper-quiet noise levels of just 28.5 dB(A) in night mode, it blends seamlessly into your home without disturbing your peace. Positioning the outdoor unit has never been easier, thanks to the Flexible Space Function and redesigned safety features. Plus, using the natural refrigerant R290, the GeniaAir Max supports a more sustainable future while keeping your home comfortable.

Specifications

Specifications

GeniaAir MaxHA 4-6 O 230V B3HA 5-6 O 230V B3HA 6-6 O 230V B3HA 8-6 O 230V B3HA 12-6 O 230V B3HA 12-6 O 400V B3HA 15-6 O 230V B3HA 15-6 O 400V B3
A7W35 heating energy label (A+++ – D)A++ (55°C) / A+++ (35°C)
Power supply230V230V230V230V230V400V230V 400V
Preheating temperature (min/max)20...75ºC20...75ºC20...75ºC 20...75ºC20...75ºC20...75ºC20...75ºC 20...75ºC
Warm-up Circuit        
Minimum operating flow rate400 l/h400 l/h 540 l/h 540 l/h995 l/h995 l/h 995 l/h 995 l/h
Maximum flow rate860 l/h860 l/1205 l/h1205 l/h2065 l/h2065 l/h2065 l/h2065 l/h
Minimum volume in the heating circuit40 l40 l40 l40 l60 l60 l60 l60 l
Heating/cooling capacity        
A7/W35 (warm-up)4,10 kW 4,20 kW5,10 kW7,80 kW11,60 kW 11,60 kW14,30 kW14,30 kW
A35/W18 (cooling)4,5 kW4,5 kW6,40 kW6,40 kW10,90 kW10,90 kW10,80 kW10,80 kW
COP (heating)/EER (cooling) (EN 14511)        
A7/W35 (warm-up)4,64,44,74,44,74,74,34,3
A35/W18 (cooling)4,34,3 4,2 4,24,64,64,64,6
SCOP (Warm climate)5,665,505,925,876,576,576,276,26
Further information        
Maximum starting current14,3 A14,3 A15,0 A15,0 A23.3 A 15,0 A23.3 A15,0 A
Type of protection IP15B IP15B IP15B IP15B IP15B IP15B IP15B IP15B
Dimensions (height × width × depth)765x1100x450 mm765x1100x450 mm965x1100x450 mm965x1100x450 mm1565x1100x450 mm1565x1100x450 mm1565x1100x450 mm1565x1100x450 mm
Hydraulic Tower – GeniaSet Max        
Dimensions:1880x595x693 mm1880x595x693 mm1880x595x693 mm1880x595x693 mm1880x595x693 mm1880x595x693 mm1880x595x693 mm1880x595x693 mm
Storage capacity:190 lts190 lts190 lts190 lts190 lts190 lts190 lts190 lts
DHW energy label (A+ – F)AAAAAAAA
Consumption profileLLLLLLLL
SCOP for DHW (Hot Climate)2,902,902,982,982,842,842,842,84
Q usable4 254 4 254 6 961 6 961 6 9616 961 6 961
Hydraulic Module – (EH 9-6 WB)        
Dimensions:720x440x350 mm720x440x350 mm720x440x350 mm720x440x350 mm720x440x350 mm720x440x350 mm720x440x350 mm720x440x350 mm