GeniaAir Max
The Max at all levels
- The Max in silence for more peace and quiet in your home
- The Max in efficiency for noticeably low operating costs
- The Max in flexibility for complete freedom when choosing the installation site
- The Max in temperature for high heating and hot water comfort
- Built to last: Reliable heating you can trust for years
The GeniaAir Max is your ideal companion for year-round comfort, offering reliable heating and cooling with top energy efficiency. Whether your home has modern systems or older radiators, this heat pump ensures warmth in winter and refreshing coolness in summer. With flow temperatures reaching up to 75°C for heating and 70°C for hot water, it’s designed to meet your needs, no matter the season. Operating at whisper-quiet noise levels of just 28.5 dB(A) in night mode, it blends seamlessly into your home without disturbing your peace. Positioning the outdoor unit has never been easier, thanks to the Flexible Space Function and redesigned safety features. Plus, using the natural refrigerant R290, the GeniaAir Max supports a more sustainable future while keeping your home comfortable.
Specifications
Specifications
| GeniaAir Max | HA 4-6 O 230V B3 | HA 5-6 O 230V B3 | HA 6-6 O 230V B3 | HA 8-6 O 230V B3 | HA 12-6 O 230V B3 | HA 12-6 O 400V B3 | HA 15-6 O 230V B3 | HA 15-6 O 400V B3 |
|---|---|---|---|---|---|---|---|---|
| A7W35 heating energy label (A+++ – D) | A++ (55°C) / A+++ (35°C) | |||||||
| Power supply | 230V | 230V | 230V | 230V | 230V | 400V | 230V | 400V |
| Preheating temperature (min/max) | 20...75ºC | 20...75ºC | 20...75ºC | 20...75ºC | 20...75ºC | 20...75ºC | 20...75ºC | 20...75ºC |
| Warm-up Circuit | ||||||||
| Minimum operating flow rate | 400 l/h | 400 l/h | 540 l/h | 540 l/h | 995 l/h | 995 l/h | 995 l/h | 995 l/h |
| Maximum flow rate | 860 l/h | 860 l/ | 1205 l/h | 1205 l/h | 2065 l/h | 2065 l/h | 2065 l/h | 2065 l/h |
| Minimum volume in the heating circuit | 40 l | 40 l | 40 l | 40 l | 60 l | 60 l | 60 l | 60 l |
| Heating/cooling capacity | ||||||||
| A7/W35 (warm-up) | 4,10 kW | 4,20 kW | 5,10 kW | 7,80 kW | 11,60 kW | 11,60 kW | 14,30 kW | 14,30 kW |
| A35/W18 (cooling) | 4,5 kW | 4,5 kW | 6,40 kW | 6,40 kW | 10,90 kW | 10,90 kW | 10,80 kW | 10,80 kW |
| COP (heating)/EER (cooling) (EN 14511) | ||||||||
| A7/W35 (warm-up) | 4,6 | 4,4 | 4,7 | 4,4 | 4,7 | 4,7 | 4,3 | 4,3 |
| A35/W18 (cooling) | 4,3 | 4,3 | 4,2 | 4,2 | 4,6 | 4,6 | 4,6 | 4,6 |
| SCOP (Warm climate) | 5,66 | 5,50 | 5,92 | 5,87 | 6,57 | 6,57 | 6,27 | 6,26 |
| Further information | ||||||||
| Maximum starting current | 14,3 A | 14,3 A | 15,0 A | 15,0 A | 23.3 A | 15,0 A | 23.3 A | 15,0 A |
| Type of protection | IP15B | IP15B | IP15B | IP15B | IP15B | IP15B | IP15B | IP15B |
| Dimensions (height × width × depth) | 765x1100x450 mm | 765x1100x450 mm | 965x1100x450 mm | 965x1100x450 mm | 1565x1100x450 mm | 1565x1100x450 mm | 1565x1100x450 mm | 1565x1100x450 mm |
| Hydraulic Tower – GeniaSet Max | ||||||||
| Dimensions: | 1880x595x693 mm | 1880x595x693 mm | 1880x595x693 mm | 1880x595x693 mm | 1880x595x693 mm | 1880x595x693 mm | 1880x595x693 mm | 1880x595x693 mm |
| Storage capacity: | 190 lts | 190 lts | 190 lts | 190 lts | 190 lts | 190 lts | 190 lts | 190 lts |
| DHW energy label (A+ – F) | A | A | A | A | A | A | A | A |
| Consumption profile | L | L | L | L | L | L | L | L |
| SCOP for DHW (Hot Climate) | 2,90 | 2,90 | 2,98 | 2,98 | 2,84 | 2,84 | 2,84 | 2,84 |
| Q usable | 4 254 | 4 254 | 6 961 | 6 961 | 6 961 | 6 961 | 6 961 | |
| Hydraulic Module – (EH 9-6 WB) | ||||||||
| Dimensions: | 720x440x350 mm | 720x440x350 mm | 720x440x350 mm | 720x440x350 mm | 720x440x350 mm | 720x440x350 mm | 720x440x350 mm | 720x440x350 mm |